Executive summary
- Britain, Norway, and the United States intercepted Russian GUGI submersibles near the Svalbard archipelago in the spring of 2026 [1].
- Western officials reported that the vessels were confronted and forced to leave the area, which successfully prevented the testing of technology designed to disable the two 1,400-kilometre fibre-optic lines connecting the archipelago to mainland Norway [1].
Britain, Norway, and the United States intercepted Russian GUGI submersibles near the Svalbard archipelago in the spring of 2026 [1]. Western officials reported that the vessels were confronted and forced to leave the area, successfully preventing the testing of technology designed to disable the two 1,400-kilometre fibre-optic lines connecting the archipelago to mainland Norway [1].
References
- Britain and NATO Allies Foil Reported Russian Drill To Disable Arctic Cables Without a Trace (ibtimes.co.uk)
ibtimes.co.uk
Standing status
Operator-reported state (read directly from each operator's own status page, not summarised by any model):
- AusInternet — network status — INDIGO West
Status: partial service disruption; Fault: shunt fault; Fault location: 65km from Perth Cable Landing Station; Repair ETA: 26 Aug 2026 / 30 Aug 2026 with an ETR on 4 Sep 2026; Delayed until: August 25th / 2nd of October NBN POI 2PTH (Penrith; Repair vessel: repairing the Shunt Fault off Perth betwee; Planned maintenance: NBN POI 3DAD (Dandenong) NNI Rehoming Planned Maintenance Schedule / September 16, 2026 12:00AM - 2:00AM AEST September 15, 2026 2:00PM - 4
as at 2026-09-10 00:09 UTC · https://ausinternet.com.au/status/ - Global Secure Layer — network status — INDIGO West
Status: partial outage; Fault: shunt fault
as at 2026-09-13 00:10 UTC · https://status.gslnetworks.com.au - SUBCO — INDIGO West — INDIGO West
as at 2026-09-13 04:17 UTC · https://sub.co/indigo-west/ - SUBCO — Oman Australia Cable, INDIGO Central, INDIGO West, SMAP
Status: monitoring
as at 2026-09-13 19:10 UTC · https://sub.co - Telstra — service status
Status: monitoring
as at 2026-09-13 13:40 UTC · https://www.telstra.com.au/exchange - Vocus — network status
Status: operational; Affected system: drum
as at 2026-08-31 01:33 UTC · https://www.vocus.com.au
Cable systems shown are those named anywhere on the captured page, matched against the systems tracked in geofences.yaml. A named system is not by itself a claim that it is the affected one.
Changes in the last 7 days:
2026-09-10 00:09AusInternet — network status — Planned maintenance: Indigo Central (Perth-Sydney) Shunt Fault Repairs Planned Maintenance → NBN POI 3DAD (Dandenong) NNI Rehoming Planned Maintenance Schedule2026-09-10 00:09AusInternet — network status — Planned maintenance: September 15, 2026 12:00AM - 2:00AM AEST September 14, 2026 2:00PM - 4 → September 16, 2026 12:00AM - 2:00AM AEST September 15, 2026 2:00PM - 42026-09-10 00:09AusInternet — network status — Planned maintenance: September 16, 2026 12:00AM - 2:00AM AEST September 15, 2026 2:00PM - 4 → September 16, 2026 11:00PM - 6:00AM AEST September 16, 2026 1:00PM - 82026-09-10 00:09AusInternet — network status — Planned maintenance: September 16, 2026 11:00PM - 6:00AM AEST September 16, 2026 1:00PM - 8 → September 17, 2026 11:00PM - 6:00AM AEST September 17, 2026 1:00PM - 82026-09-10 00:09AusInternet — network status — Planned maintenance: September 17, 2026 11:00PM - 6:00AM AEST September 17, 2026 1:00PM - 8 → October 2, 2026 10:00AM - 9:00AM AEST October 2, 2026 12:00AM2026-09-10 00:09AusInternet — network status — System named on page: INDIGO Central → INDIGO West2026-09-10 00:09AusInternet — network status — System named on page: INDIGO West → (removed)2026-09-09 16:11AusInternet — network status — Planned maintenance: September 16, 2026 11:00PM - 6:00AM AEST September 16, 2026 1:00PM - 8 → September 17, 2026 11:00PM - 6:00AM AEST September 17, 2026 1:00PM - 82026-09-09 16:11AusInternet — network status — Planned maintenance: September 15, 2026 12:00AM - 2:00AM AEST September 14, 2026 2:00PM - 4 → September 16, 2026 12:00AM - 2:00AM AEST September 15, 2026 2:00PM - 42026-09-09 16:11AusInternet — network status — Planned maintenance: Indigo Central (Perth-Sydney) Shunt Fault Repairs Planned Maintenance → September 15, 2026 12:00AM - 2:00AM AEST September 14, 2026 2:00PM - 42026-09-09 16:11AusInternet — network status — Planned maintenance: Data Centres → Indigo Central (Perth-Sydney) Shunt Fault Repairs Planned Maintenance2026-09-09 16:11AusInternet — network status — Planned maintenance: September 16, 2026 12:00AM - 2:00AM AEST September 15, 2026 2:00PM - 4 → September 16, 2026 11:00PM - 6:00AM AEST September 16, 2026 1:00PM - 82026-09-09 14:10AusInternet — network status — Planned maintenance: NBN POI 3CBN (Cranbourne) - NNI Rehoming Planned Maintenance Schedule → Data Centres2026-09-09 14:10AusInternet — network status — Planned maintenance: September 10, 2026 10:00AM - 10:00AM AEST September 10, 2026 12:00AM → Indigo Central (Perth-Sydney) Shunt Fault Repairs Planned Maintenance2026-09-08 16:10AusInternet — network status — Planned maintenance: September 15, 2026 12:00AM - 2:00AM AEST September 14, 2026 2:00PM - 4 → September 16, 2026 12:00AM - 2:00AM AEST September 15, 2026 2:00PM - 42026-09-08 16:10AusInternet — network status — Planned maintenance: September 10, 2026 10:00AM - 10:00AM AEST September 10, 2026 12:00AM → September 15, 2026 12:00AM - 2:00AM AEST September 14, 2026 2:00PM - 42026-09-08 16:10AusInternet — network status — Planned maintenance: NBN POI 3CBN (Cranbourne) - NNI Rehoming Planned Maintenance Schedule → September 10, 2026 10:00AM - 10:00AM AEST September 10, 2026 12:00AM2026-09-08 16:10AusInternet — network status — Planned maintenance: Data Centres → NBN POI 3CBN (Cranbourne) - NNI Rehoming Planned Maintenance Schedule2026-09-08 16:10AusInternet — network status — Planned maintenance: September 16, 2026 12:00AM - 2:00AM AEST September 15, 2026 2:00PM - 4 → September 16, 2026 11:00PM - 6:00AM AEST September 16, 2026 1:00PM - 82026-09-08 14:11AusInternet — network status — Planned maintenance: NBN POI 3CAU (Caulfield) NNI Rehoming Planned Maintenance Schedule → Data Centres
Incident threads:
other— 77 documents, last 2026-09-13 (quiet 1d)perth_indigo_2026_08(INDIGO West, INDIGO Central) — 13 documents, last 2026-09-09 (quiet 5d)
Measured path state (RIPE Atlas traceroute, median across probes over 24h, no model involved):
- perth to singapore — ocean crossing 150.3ms; queuing 0.6ms; end to end floor 273.3ms, +70.9ms against its 24 day baseline; clean crossing (21 probe(s), 34 reading(s) excluded as below the corridor's physical floor)
- sydney to japan — ocean crossing 133.2ms; queuing 0.5ms; end to end floor 177.7ms, +34.8ms against its 24 day baseline; clean crossing (16 probe(s))
- sydney to nz — ocean crossing 27.5ms; queuing 0.2ms; end to end floor 34.4ms, steady against its 24 day baseline; clean crossing (8 probe(s))
- sydney to singapore — ocean crossing 152.0ms; queuing 0.7ms; end to end floor 223.7ms, +23.2ms against its 24 day baseline; clean crossing (21 probe(s))
A corridor is a city pair, not a cable. Several systems serve each of these routes and IP routing does not reveal which one carries a packet, so a healthy corridor is not evidence that any particular cable is intact: traffic reroutes onto a survivor within seconds of a fault. Per-probe detail is in cablewatch segments.
Vessel review queue:
darwin_cpz_standing(North West Cable System, Timor-Leste South Submarine Cable System) — 5 candidate(s), top review priority 0.40sydney_cpz_standing(Australia Singapore Cable, Southern Cross NEXT, Hawaiki, Southern Cross Cable Network, Tasman Express, Tasman Ring, Japan Guam Australia -North, Japan Guam Australia -South) — 5 candidate(s), top review priority 0.35perth_cpz_2026_08(INDIGO West, INDIGO Central) — 4 candidate(s), top review priority 0.33
Review priority is a heuristic score from this repo ordering which tracks a human should look at. It is not evidence, and it implies nothing about any vessel.
Collection: 954 successful fetches in 24h, 48 errors across 13 source(s). Generated 2026-09-13 19:11 UTC.